Underfloor Heating Pipe Calculator — How Much Pipe Do I Need?

Calculate the total pipe length and number of coils for your underfloor heating installation. UK standard pipe spacings and sizes.

Standard coil size you plan to buy

Distance from manifold to room (one way)

Include wastage allowance

Adds 5% extra for cutting waste and layout variations

5% recommended for professionals, 10% for DIY or complex layouts

Enter your supplier price for a cost estimate

How We Calculate This

Our underfloor heating pipe calculator determines the total pipe length based on your floor area and chosen pipe spacing, then calculates how many standard coils you need to order.

The formula

Pipe length = (Floor area ÷ Pipe spacing) + Manifold allowance

For example, a 20 m² room at 150mm spacing needs: 20 ÷ 0.15 = 133m of pipe, plus approximately 8m for manifold connections (4m each way for flow and return), giving ~141m total. With 5% wastage: ~148m. You would need 2 x 100m coils.

Circuit planning

We check whether the total pipe length exceeds the recommended maximum loop length for your pipe diameter. If it does, we advise splitting into multiple circuits, each connected to the manifold independently. This ensures even heat distribution and avoids excessive pressure drop, in line with BS EN 1264 (Water based surface embedded heating and cooling systems).

Standard coil sizes

  • 50m coil: Small rooms and top-ups
  • 100m coil: Most popular domestic size
  • 120m coil: Common mid-size option
  • 150m coil: Larger installations

Frequently Asked Questions

Last updated: February 2026

All calculations are estimates. Verify with your supplier.