How We Calculate This
Our hot water cylinder calculator estimates the correct capacity based on the number of occupants and their hot water usage patterns. The calculation follows UK industry guidelines for domestic hot water demand.
The calculation method
Daily demand = Number of occupants x Usage per person per day
We estimate daily hot water usage at 60°C as:
- Shower only: ~35 litres per person per day
- Bath & shower: ~45 litres per person per day
- Mostly baths: ~55 litres per person per day
Peak demand sizing
The cylinder does not need to store an entire day's hot water — it reheats throughout the day. We size based on peak demand (65-75% of daily usage), which represents the busiest period (typically morning). Multi-bathroom homes need a higher peak factor because multiple outlets may be used simultaneously.
Standard UK sizes
We recommend the nearest standard UK cylinder size that meets or exceeds your peak demand: 90L, 120L, 150L, 180L, 210L, 250L, or 300L. These align with commonly available products from manufacturers like Megaflo, Heatrae Sadia, and Telford.
Frequently Asked Questions
Related Calculators
Pipe Sizing Calculator
Calculate the correct pipe diameter for your plumbing installation.
Boiler Size Calculator
Determine the right boiler kW output for your UK property.
Radiator Sizing Calculator
Calculate the BTU output needed for each room.
Central Heating System Volume Calculator
Calculate total water volume in your central heating system.
Inhibitor Dosing Calculator
Work out the correct amount of inhibitor for your heating system.
Last updated: February 2026
All calculations are estimates. Verify with your supplier.