Consumer Unit Sizing Calculator — How Many Ways Do I Need?
Calculate the right consumer unit size for your property based on BS 7671 18th Edition. Includes spare ways for future expansion.
Preset loads typical circuits automatically
20% recommended for future expansion
32A dedicated circuit for electric cooker
40A dedicated circuit for electric shower
16A dedicated circuit
32A dedicated circuit for 7kW charger
6A dedicated circuit
16A dedicated circuit
16A dedicated circuit
6A dedicated circuit — required by Building Regs
How We Calculate This
This calculator determines the consumer unit size you need by counting all required circuits for your property and adding spare ways for future expansion, following BS 7671 18th Edition guidelines.
The formula
Total ways = Number of circuits + Spare ways (min 20% or 2 ways)
The calculator then rounds up to the nearest standard consumer unit size available in the UK: 6, 10, 12, 16, 18, or 21 ways.
Standard UK circuit MCB ratings
- Lighting circuits: 6A Type B MCB
- Ring main (sockets): 32A Type B MCB
- Cooker circuit: 32A Type B MCB
- Electric shower: 40A Type B MCB (for up to 9.5kW)
- Immersion heater: 16A Type B MCB
- EV charger (7kW): 32A Type B MCB
- Smoke detectors: 6A Type B MCB
Frequently Asked Questions
Related Calculators
Cable Sizing Calculator
Calculate the correct cable size based on BS 7671 18th Edition regulations.
Voltage Drop Calculator
Check voltage drop complies with UK wiring regulations.
Maximum Demand Calculator
Calculate maximum electrical demand for domestic installations.
Circuit Breaker Sizing Calculator
Determine the correct MCB rating for your circuit.
Socket Spacing Calculator
Plan socket layouts with Part P guidance on spacing and positioning.
Last updated: February 2026
All calculations are estimates. Verify with your supplier.